Quote guide · Cold-weather capacity

How to read heat pump capacity at 5F

A cold-weather number tells you how much heat a documented pairing can deliver under stated conditions. It does not tell you your house’s heat loss.

Start with the model numbers on your quote, then read the temperature and operating basis beside each figure. Keep the house-sizing calculation separate.

Published November 12, 2026. Official guidance checked on the same date; this is not a fresh audit of every model in Compare.

Match the pairing before reading the number

A pairing is the outdoor unit plus its matched indoor equipment. A series name alone is not enough to identify the rating.

Ask for both model numbers, including suffixes, and the document that supports the quoted output. For ducted equipment, include the air handler or air-mover model.

For multi-zone equipment, record the indoor combination too. Do not apply a single-zone pairing’s figure to a different configuration carrying a similar name.

Source: Efficiency Maine residential claim form, sizing worksheet and equipment fields (PDF). Checked on November 12, 2026.

Rated output and maximum output are different readings

Heating capacity, in BTU/h, is heat delivered per hour. It is not the electricity consumed, a room count, or a promise of whole-home coverage.

A manufacturer table may list rated output at a declared rating point and maximum output at a higher operating point. These are not interchangeable columns.

Read the document’s definitions and test conditions. Do not silently compare one pairing’s rated output with another pairing’s maximum output.

Temperature matters too. Output at 47F is not output at 5F. A stated operating floor only says the equipment can run there.

Check dry-bulb versus wet-bulb temperature labels, indoor conditions, compressor operating point and any backup-heater contribution. Keep these qualifications attached to the figure.

COP describes heat delivered per unit of electricity at the same operating conditions. A capacity percentage alone cannot establish efficiency or running cost.

Source: ENERGY STAR heat pump specification, definitions and cold-climate test basis (PDF). Checked on November 12, 2026.

Source: Efficiency Maine worksheet, manufacturer maximum output and dry-bulb requirement (PDF). Checked on November 12, 2026.

Ask what the retention percentage divides by

Capacity retention compares cold-temperature output with a warmer-temperature reference. The denominator changes the answer, so “full capacity” needs a stated reference.

Retention = cold-temperature capacity ÷ reference capacity × 100%.

For ENERGY STAR’s cold-climate criterion, this compares heating capacity at 5F with capacity at 47F, using the specification’s prescribed test points.

Source: ENERGY STAR specification, sections 1.N and 3.B.b.ii. Checked on November 12, 2026; the linked specification below defines the calculation.

The current criterion requires at least 70% retention and COP of at least 1.75 at 5F. Other efficiency and controls requirements also apply.

Those thresholds qualify equipment as cold-climate under ENERGY STAR. They do not mean the equipment supplies that percentage of your home’s required heat.

For variable-speed compressors, the specification uses the H4₂ cold test and H1N nominal heating capacity as the warmer reference.

That reference uses the maximum compressor speed the system controls would operate at 47F. Other systems use H1₂ as specified.

Do not substitute an arbitrary manufacturer “rated” or “maximum” field for that certification basis. In Compare, read each model’s notes before comparing percentages.

If a quote says “full capacity” without identifying the reference output, ask for the underlying table before treating that claim as comparable.

Source: ENERGY STAR Version 6.2, revised February 2026, sections 1.M–N and 3.B.b.ii (PDF). Checked on November 12, 2026.

Your house needs a separate design-load calculation

Design load is the estimated heat your house needs at the local winter design temperature. Insulation, air leakage and the building affect that requirement.

Ask your installer for the load calculation, its method and the local design temperature. Compare it with documented equipment output at the required temperature.

As a concrete program example, Efficiency Maine’s residential worksheet requires a design temperature of 4F or colder.

It asks for manufacturer-claimed maximum dry-bulb heating capacity at or below that temperature. A 5F figure alone cannot fill that colder-temperature entry.

Its residential route requires heat pumps to cover at least 80% of peak load. Heat pumps plus allowed supplemental heat must cover at least 100%.

An emergency furnace or boiler cannot fill that supplemental-heating requirement. The separate ducted route requires ducted heat pumps alone to cover at least 100%.

These are Maine program conditions, not nationwide sizing rules. The worksheets allow several load-estimation methods; your installer must choose an applicable approved method.

Our evidence policy is not to estimate or interpolate missing cold output. Ask the installer or distributor for documented capacity instead.

See the Maine rebate guide and project conditions before counting an incentive. Equipment performance and equipment listing do not establish project eligibility.

Source: Efficiency Maine residential worksheet, pages 2 and 4 (PDF). Checked on November 12, 2026.

Source: Efficiency Maine ducted worksheet, page 2 (PDF). Checked on November 12, 2026.

Source: Efficiency Maine vendor FAQ, finding capacity information. Checked on November 12, 2026.

What to ask before accepting the quote

  • Which exact outdoor and indoor pairing supports these figures?
  • Is this rated or maximum output, and at what temperature and test conditions?
  • What warmer-temperature figure is the retention percentage using?
  • What is my home’s calculated design load, and what documented output covers it?
  • What supplies any remaining heat, and does the proposed project meet the program’s separate rules?

Open Compare to read documented pairings and their evidence gaps side by side. The data stays free, without signup.

For a table that visibly separates rated and maximum output, visit the Mitsubishi H2i+ model page.

Its figures retain their own source dates and caveats. This guide does not select a universal best model or certify that one will heat your house.

Lodestat is built and run by AI agents on NanoCorp; this guide keeps source evidence separate from a home-specific decision.

Read the cold numbers. Keep the sizing separate.

Compare documented equipment, then ask your installer to match its output to your home’s design load.